History of the endovenous laser Endotherme™ 1470

After the success of the Pharaoh 980nm and following the validation of the clinical interest of the 1470nm wavelength, LSO Medical launched the 1470nm Endotherm™ in 2012.

This wavelength of 1470nm combined with its “continuous” firing mode are now recognized as the Gold Standard in the thermal ablation treatment of saphenous by Laser.

Internationally :

Technical characteristics
Why the wavelength 1470 nm?

a) Selective energy delivery

The Endotherme™ 1470 laser emits infrared light with a wavelength of 1470nm.

Emitted inside the saphenous, the light is thus absorbed by the water (its chromophore) of the venous wall and then converted into heat.

Under the effect of this heat, the venous wall is destroyed, which leads to the occlusion of the saphenous.

Indications

The precise targeting of the 1470m Endovenous Laser allows a high precision of the treatment as well as wide indications.

The Endovenous Laser is indicated for:

  • Large saphenous veins (between 4 and 20 mm in diameter in orthostatic position)
  • Small saphenous veins (between 4 and 20 mm in diameter in orthostatic position)

And their associated complementary acts:

  • Accessory saphenous
  • Perforating veins

Contraindications

Endotherme™ 1470 should not be used in the following cases:

  • Patients with thrombi in the venous segment intended for treatment.
  • Patients with an aneurysm in the venous segment intended for treatment.
  • Patients with peripheral vascular diseases with an ankle-arm systolic pressure index below 0.9.
  • Patients with deep vein thrombosis or with a history of deep vein thrombosis
  • Pregnant patients
  • Patients with infection on the area to be treated, active herpes or other viral infection.
  • Other contraindications may be indicated by the practitioner at the time of treatment

Thermal Endovenous Treatment – The Equipment

LSO Medical offers you a turnkey solution to launch a thermal endovenous activity.

You want to discuss your business project:

 

b) Focused energy delivery

The penetration distance of the wavelength 1470 is of the order of 300 to 400 μm.

During thermal endovenous treatment, the 1470 laser acts on more than half the thickness of the venous wall (thickness between 450 and 600 μm), inducing a level of tissue damage necessary (to induce the destruction of the vein) and sufficient (not to induce damage in the surrounding tissues)

Conclusion

Wavelength Diode Laser 1470 nm + Radial Emission Fibers:

  • Low light penetration (0.34mm) by LO 1470 nm
  • Light oriented towards the venous wall by the radial emission fiber
  • Short exposure time (thanks to continuous shrinkage)

=> Destruction of the Wall without destruction of surrounding tissues or nerves

Technical specifications:
  • Laser: Laser Diode
  • Wavelength: 1470 nm +/-10
  • Power: 15 Watts
  • Cooling: Peltier and Air
  • Operation:
  • Certification:
  • Continuous or Pulsed, 0.1 to 25 sec.
  • Laser class: 4
  • Class DM: IIb (Directive 93/42/EC)
  • Power supply: 100-230 VAC; 50 to 60 Hz
  • Weight: 15 kg
  • Dimensions: H 45cm × L 45cm × W 35cm
Related accessories

LSO Medical offers you a turnkey solution to launch a thermal endovenous activity.

You want to discuss your business project: Contact LSO Medical

a) Laser fiber Ringlight®

Libellé Reference Technical specifications Compatibility
Fibre Ringlight® Standard

CE1639

ORLF000003 600 µm, 1.8 mm Laser : Endotherme™ 1470

Introducteur : Introducteur 6 Fr

Fibre Ringlight® Slim

CE1639

ORLF000005 400 µm, 1.0 mm Laser : Endotherme™ 1470

Introducteur : Introducteur 4 Fr ou Cathlon 16G

Fibre Ringlight® Fused Standard

CE1639

ORLF000007 600 µm, 1.8 mm Laser : Endotherme™ 1470

Introducteur : Introducteur 6 Fr

Fibre Ringlight® Fused Slim

CE1639

ORLF000006 400 µm, 1.3 mm Laser : Endotherme™ 1470

Introducteur : Introducteur 4 Fr ou Cathlon 16G

Compatibility :

Legal Notice

Destinations: vascular surgeons, vascular doctors, pharmacists, biomedical engineers and operating room staff.

DM class: IIb. Laser class: 4.

Disposables: Ringlight® and Ringlight_SB® Laser Fibers

Indications: Medical lasers and sterile disposables for endovascular coagulation, occlusion and removal of saphenous veins.

Contraindication: Endotherme™ should not be used in the following cases: Patients with thrombi in the venous segment intended for treatment, Patients with an aneurysm in the venous segment intended for treatment, Patients with peripheral vascular diseases with an ankle-arm systolic pressure index below 0.9,  Patients with deep vein thrombosis or with a history of deep vein thrombosis, Pregnant patients, Patients with infection on the area to be treated, active herpes or other viral infection, Other contraindications may possibly be indicated by the practitioner at the time of treatment. Read the instructions in the user manual carefully.

Endovenous Laser Treatment: Covered by Health Insurance

Manufacturer: LSO Medical, Biocentre Fleming, Bât D, 280 rue Salvador Allende, 59120 Loos, France

Distributor: SCW brands.

Internal reference: 23/04/LSOMEDICAL/PM/001

Version: IM EMB – VA-en